0032413
0032413
LAPP Cable
Instrumentation cable with reinforced outer sheath`
RE-2Y(ST)Yv: PVC computer data cables, 7-wire Cu conductor, Low capacitance, Paired stranding, Screened/ Static Foil, PVC jacket, Black or blue, Flame retardant
Contact us for Lead Time
Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.
0032413 Specifications
- Outer sheath colour:
- black for outdoor applications or
- blue for intrinsically safe systems
- Flame-retardant according IEC 60332-1-2
| Attribute | Value |
|---|---|
| Product Brand Name | UNITRONIC® RE-2Y(ST)Yv |
| Approvals | In the style of EN 50288-7 |
| Approvals |
|
| Extended Description |
Benefits
|
| Benefits | Aluminium-laminated plastic foil static screen with tin-plated drain wire minimises the interference of high frequency, electromagnetic fields | Decoupling of circuits by means of | twisted-pair (TP) design (crosstalk effects) | Low capacitance due to polyolefin-based insulation |
| Outdoor Use | Yes |
| UV Resistant | Yes |
| Interference rejecting | Yes |
| Number of conductors | 4X2 |
| mm2 per conductor | 0.5 |
| Outer Diameter (mm) | 11.1 |
| Copper index kg per km | 50 |
| Core Identification Code | a-core: black; b-core: white with consecutive numbers: 1-1, 2-2, 3-3, 4-4 etc. Three-way version: black, white, red |
| Characteristic impedance | approx. 100 ohms |
| Characteristic impedance |
|
| Conductor resistance | 0.5 mm²: max. 39.2 ohm/km | 1.3 mm²: max. 14.3 ohm/km |
| Conductor resistance HTML |
|
| Test Voltage |
|
| Benefits |
|
| Product Make Up |
|
| Product Make Up | 7-wire bare stranded copper conductor, core insulation made of polyethylene (PE), cores twisted into pairs, pairs stranded in layers | Complete stranding contains 1 core for communication (core colour orange) | the communication core is omitted on single-pair versions | Foil wrapping, static screening made of aluminium-laminated plastic film with tinned drain wire | Reinforced outer sheath made of PVC | Outer sheath colour: black (RAL 9005) or blue (RAL 5015) |
| Test Voltage | Core/core: 2000 V | Core/screen: 1000 V |
| Core Identification Code HTML |
|
| Minimum Bending Radius | Occasional flexing: 15 x outer diameter | Fixed installation: 7.5 x outer diameter |
| Minimum Bending Radius |
|
| Temperature Range |
|
| Technical Data |
Core identification code
|
| Applications |
|
| Weight kg per km | 140 |
| Temperature Range | Occasional flexing: -5°C to +50°C | Fixed installation: -40°C to +80°C |
| Applications | In measurement and control engineering | Electrically intended for use when modern process computers have to process large volumes of data, e.g. high-capacity computer systems in waste incineration plants or sewage treatment plants | These cables are suitable for fixed installation in dry or damp rooms and, in case of versions with a black outer sheath, also for outdoor use | Thanks to reinforced, nominal/ minimum average wall thickness of the outer sheath of at least 1.8 mm, for applications, where a reinforced outer sheath may turn out to be advantageous. |
| Features | Outer sheath colour: | black for outdoor applications or | blue for intrinsically safe systems | Flame-retardant according IEC 60332-1-2 |
| Attribute | Value |
|---|---|
| Data Sheet | Click here to view |