0034192

0034192

0034192

LAPP Cable

Static screened installation cable for industrial electronics

JE-Y(ST)Y...BD installation cable for industrial electronics, VDE 0815, PVC, solid conductor, pairs, bundle laying, screened/ static foil, stationary use
Contact us for Lead Time

Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.

0034192 Specifications

  • The 2-pair version (2x2x0.8) is twisted into a star quad
  • Flame-retardant according IEC 60332-1-2
  • JE-Y(ST)Y...BD EB: For intrinsically safe circuits (type of protection i - intrinsic safety) according to IEC 60079-14:2013 / EN 60079-14:2014 / VDE 0165-1:2014, section 16.2.2
More Information
Attribute Value
Product Brand Name JE-Y(ST)Y...BD
Approvals In accordance with DIN VDE 0815type JE-Y(ST)Y...BD
Approvals
  • In accordance with DIN VDE 0815type JE-Y(ST)Y...BD
Extended Description Benefits
  • Perfect for cost-effective installation, e.g. connections with insulation displacement technology (IDC).
  • Aluminium-laminated plastic foil static screen with tin-plated drain wire minimises the interference of high frequency, electromagnetic fields
  • Decoupling of circuits by means of twisted-pair (TP) design (crosstalk effects)
Features
  • The 2-pair version (2x2x0.8) is twisted into a star quad
  • Flame-retardant according IEC 60332-1-2
  • JE-Y(ST)Y...BD EB: For intrinsically safe circuits (type of protection i - intrinsic safety) according to IEC 60079-14:2013 / EN 60079-14:2014 / VDE 0165-1:2014, section 16.2.2
Product make up
  • Solid bare copper conductor
  • Core insulation made of PVC
  • 2 cores twisted into a pair, and 4 pairs into units (for 2 x 2 x 0.8 as star quad cable)
  • Foil wrapping, static screening made of aluminium-laminated plastic film with copper drain wire
  • Outer sheath made of PVC
  • Outer sheath colour: grey (similar to pebble grey/ RAL 7032)
Benefits Perfect for cost-effective installation, e.g. connections with insulation displacement technology (IDC). | Aluminium-laminated plastic foil static screen with tin-plated drain wire minimises the interference of high frequency, electromagnetic fields | Decoupling of circuits by means of twisted-pair (TP) design (crosstalk effects)
Interference rejecting Yes
Number of conductors 8X2
mm2 per conductor 0.8
Outer Diameter (mm) 11
Copper index kg per km 85
Core Identification Code according to VDE 0815
Conductor resistance max. 73.2 Ohm/km
Conductor resistance HTML
  • max. 73.2 Ohm/km
Test Voltage
  • Core/core: 500 V
  • Core/screen: 2000 V
Benefits
  • Perfect for cost-effective installation, e.g. connections with insulation displacement technology (IDC).
  • Aluminium-laminated plastic foil static screen with tin-plated drain wire minimises the interference of high frequency, electromagnetic fields
  • Decoupling of circuits by means of twisted-pair (TP) design (crosstalk effects)
Product Make Up
  • Solid bare copper conductor
  • Core insulation made of PVC
  • 2 cores twisted into a pair, and 4 pairs into units (for 2 x 2 x 0.8 as star quad cable)
  • Foil wrapping, static screening made of aluminium-laminated plastic film with copper drain wire
  • Outer sheath made of PVC
  • Outer sheath colour: grey (similar to pebble grey/ RAL 7032)
Product Make Up Solid bare copper conductor | Core insulation made of PVC | 2 cores twisted into a pair, and 4 pairs into units (for 2 x 2 x 0.8 as star quad cable) | Foil wrapping, static screening made of aluminium-laminated plastic film with copper drain wire | Outer sheath made of PVC | Outer sheath colour: grey (similar to pebble grey/ RAL 7032)
Test Voltage Core/core: 500 V | Core/screen: 2000 V
Inductivity approx. 0.65 mH/km
Core Identification Code HTML
  • according to VDE 0815
Conductor Stranding Single-wire (solid conductor) 0.8 mm: 0.50 mm²
Conductor Stranding HTML
  • Single-wire (solid conductor) 0.8 mm: 0.50 mm²
Minimum Bending Radius Fixed installation: 6 x outer diameter
Minimum Bending Radius
  • Fixed installation: 6 x outer diameter
Temperature Range
  • Occasional flexing: -5°C to +50°C
  • Fixed installation: -30°C to +70°C
Technical Data Core identification code
  • according to VDE 0815
Conductor stranding
  • Single-wire (solid conductor) 0.8 mm: 0.50 mm²
Minimum bending radius
  • Fixed installation: 6 x outer diameter
Test voltage
  • Core/core: 500 V
  • Core/screen: 2000 V
Inductivity
  • approx. 0.65 mH/km
Conductor resistance
  • max. 73.2 Ohm/km
Temperature range
  • Occasional flexing: -5°C to +50°C
  • Fixed installation: -30°C to +70°C
Weight kg per km 158
Temperature Range Occasional flexing: -5°C to +50°C | Fixed installation: -30°C to +70°C
Features The 2-pair version (2x2x0.8) is twisted into a star quad | Flame-retardant according IEC 60332-1-2 | JE-Y(ST)Y...BD EB: For intrinsically safe circuits (type of protection i - intrinsic safety) according to IEC 60079-14:2013 / EN 60079-14:2014 / VDE 0165-1:2014, section 16.2.2
More Information
Attribute Value
Data Sheet Click here to view

Related Products

  1. 0034176
  2. 0032420
  3. 0031320
  4. 0034224
  5. 0028225