The store will not work correctly in the case when cookies are disabled.
1123274
1123274
LAPP Cable
Screened halogen-free control cable with improved fire characteristics
ÖLFLEX® CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U0/U: 300/500V
More Information
Attribute |
Value |
Product Brand Name |
ÖLFLEX® CLASSIC 135 CH |
Approvals |
- UL AWM style 21217
- Based on EN 50525-3-11
- Based on EN 50525-2-51
- DNV GL certificate no. TAE00002RK
|
Extended Description |
Benefits- Easy installation due to flexible design
- Space-saving installation due to small cable diameters
- Certified for maritime applications
Applications- Public buildings like airports or railway stations
- Plant engineering, Industrial machinery, Heating and air-conditioning systems
- Particularly where human and animal life as well as valuable property are exposed to high risk of fire hazards
- In EMC-sensitive environments (electromagnetic compatibility)
Features- Flame-retardant according to IEC 60332-1-2 (flame spread on a single cable)
- No flame-propagation according to IEC 60332-3-22 and IEC 60332-3-24 respectively IEC 60332-3-25 (Flame spread on vertical cable or wire bundle)
- Halogen-free according to IEC 60754-1 (amount of halogen acid gas) - Corrosiveness of combustion gases according to IEC 60754-2 (degree of acidity)
- Low smoke density according to IEC 61034-2
Product make up- Fine-wire strand made of bare copper wires
- Core insulation: Halogen-free
- Cores twisted in layers
- Halogen-free plastic foil wrapping
- Tinned-copper braiding
- Outer sheath: Special halogen-free compound, grey (similar to RAL 7001)
|
Manufacturer |
Lapp |
Halogen free |
Yes |
Flame Retardant |
Yes |
Interference rejecting |
Yes |
Number of conductors |
7 |
mm2 per conductor |
1 |
Protective Conductor |
Yes |
Outer Diameter (mm) |
8.9 |
Copper index kg per km |
112.0000 |
Benefits |
- Easy installation due to flexible design
- Space-saving installation due to small cable diameters
- Certified for maritime applications
|
Technical Data |
Core identification code- Black with white numbers acc. to VDE 0293-334
Conductor stranding- Fine wire according to VDE 0295,, class 5/IEC 60228 class 5
Minimum bending radius- Occasional flexing: 20 x outer diameter
- Fixed installation: 6 x outer diameter
Nominal voltageTest voltage- Core/core: 4000 V
- Core/screen: 2000 V
Temperature range- Occasional flexing: -25°C to +70°C (UL: +75°C)
- Fixed installation: -40°C to +80°C (UL: +75°C)
|
Weight kg per km |
155.0000 |