15500113
15500113
LAPP Cable
Fixed installation, direct burial; PVC cable with different application areas
NYY-J, NYY-O, VDE, PVC-Starkstromkabel acc. HD 603 / VDE 0276-603, direct burial and building installation, fixed installation with various applications
Contact us for Lead Time
Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.
15500113 Specifications
- Flame-retardant according IEC 60332-1-2
- Current rating according to HD 603/VDE 0276-603, Part 3-G, Table 14 (buried at +20 °C ground temperature according to HD 603/VDE 0276-603, Part 3-G, point 5) for routing underground and Table 15 (in the air at an air temperature of +30 °C according to HD 603/VDE 0276-603, Part 3-G, point 5) when used outdoors; but always taking into consideration corrections/reductions to the current rating that may be necessary according to VDE 0298-4, and VDE 0298-4 (also refer to the catalogue appendix T12) for installation in and on buildings
- Maximum DC voltage to ground 1,8 kV according to HD 603 / DIN VDE 0276-603
| Attribute | Value |
|---|---|
| Product Brand Name | NYY-J |
| Approvals | HD 603/VDE 0276-603 (for 1 to 5 cores) | HD 627/VDE 0276-627 (as from 7 cores) |
| Approvals |
|
| Extended Description |
Applications
|
| Manufacturer | Lapp |
| Outdoor Use | Yes |
| Number of conductors | 4 |
| mm2 per conductor | 2.5 |
| Protective Conductor | No |
| Outer Diameter (mm) | 14 |
| Copper index kg per km | 96 |
| Core Identification Code | Up to 5 cores: colour-coded according to VDE 0293-308, refer to Appendix T9 | From 6 cores: black with white numbers |
| Nominal Voltage | U0/U: 0.6/1.0 kV |
| Test Voltage |
|
| Product Make Up |
|
| Product Make Up | Bare copper wire conductor | Core insulation: Based on PVC | Filling compound over the core assembly | Outer sheath: Based on PVC |
| Test Voltage | 4000 |
| Core Identification Code HTML |
|
| Conductor Stranding | Single or multi-wire |
| Conductor Stranding HTML |
|
| Minimum Bending Radius | Single-core: 15 x outer diameter | Multi-core: 12 x outer diameter |
| Minimum Bending Radius |
|
| Nominal Voltage HTML |
|
| Temperature Range |
|
| Technical Data |
Core identification code
|
| Applications |
|
| Weight kg per km | 316 |
| Temperature Range | During installation: -5°C to +50°C | Fixed installation: -40°C to +70°C |
| Applications | For indoor and outdoor use | Burial without additional, suitable underground protection according to VDE standard HD 603/VDE 0276-603 - Part 3-G (point 4) governing PVC cables for direct burial: normal minimum installation depth 0.6 m, but at least 0.8 m under roads | In concrete with a temperature below the maximum cable operating temperature of +70 °C according to the VDE standard HD 603/VDE 0276-603 - Part 3-G (point 4) governing PVC cables for direct burial |
| Features | Flame-retardant according IEC 60332-1-2 | Current rating according to HD 603/VDE 0276-603, Part 3-G, Table 14 (buried at +20 °C ground temperature according to HD 603/VDE 0276-603, Part 3-G, point 5) for routing underground and Table 15 (in the air at an air temperature of +30 °C according to HD 603/VDE 0276-603, Part 3-G, point 5) when used outdoors; but always taking into consideration corrections/reductions to the current rating that may be necessary according to VDE 0298-4, and VDE 0298-4 (also refer to the catalogue appendix T12) for installation in and on buildings | Maximum DC voltage to ground 1,8 kV according to HD 603 / DIN VDE 0276-603 |
| Attribute | Value |
|---|---|
| Data Sheet | Click here to view |