2490400
2490400
HAEFELY AG
AXOS5 Compact - Compact EMC Test System for Surge, EFT/Burst, Dips, and Magnetic Field
The new Haefely AXOS5 - Compact integrates all of the best features of a Haefely standalone test system into one single economic solution.
Combination Wave, 5 kV EFT/Burst, Dips & Interrupts, along with an integrated single-phase coupling / decoupling network. This allows quick and completely automated testing to the most common IEC, EN, ANSI, IEEE and UL standards.
The AXOS5 can either be operated via the front panel by a large colour graphic interface or remotely from the PC. The easy-to-use menu, together with the availability of predefined test routines for different standards, makes testing easy and reliable, even for less frequent users. Numerous additional functions, such as an external start/stop function, allow easy integration of the test system also in customer-specific test environments.
All the test parameters can be varied in a broad range wide above the requirements of the standards. Together with the ability to change test parameters during test, AXOS5 is not only the ideal product for compliance and pre-compliance testing, it is useful for monitoring & debugging functions during the design phase as well.
A wide range of cost-efficient and user-friendly coupling/decoupling networks for power lines, as well as for symmetrical and asymmetrical data and signal lines, is available as options.
Key Features
- Easy to operate with manual and automated test modes, software assisted test preparation, pre-defined test routines and visual aided test setups
- Economic and Efficient: Touch screen guarantees reduction of time and effort - Experience and know-how at a reasonable price
- Multiple testing functions available in a single unit
- Safe and reliable operation by using safety interlock, warning lamp and emergency stop functions
- Voltage and current monitoring of surge impulses and EUT power provides valuable feedback to the test engineer
- Automatic generation of test report, including test parameters, test setup and test result
Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.
| Attribute | Value |
|---|---|
| Included Accessories | Mains Cable, User Manual, Calibration certificate |
| Dimensions | 19“ / 4U (45 x 18 x 49 cm) |
| Weight | 25 kg |
| Standards |
|
| Applications |
|
| Control Power | 85 V - 264 V; 50/60Hz |
| User Test Storage | Unlimited |
| Remote Interface | Ethernet, RJ45 |
| Display | 7“ / 800x480 / 24 bit with touchscreen |
| External Trigger Input | 5 V TTL |
| Trigger Output | 5 V TTL |
| EUT Failed Input | 5 V TTL |
| Warning Lamp Output | 2 x 24 V / 1 A DC |
| USB | For USB memory stick |
| AUX Interface | D-sub 37p for external CDN, external transformer etc… |
| Sync Input | BNC, 10 V – 264 V AC |
| External Start/Stop Input | 5 V TTL, starts / stops predefined test sequence |
| Analogue Output | 0-10 V, for use with external options |
| Safety Circuit | Stops the test when unlocked |
| EFT/Burst: Output Voltage | 0.2–5.0 kV ±10% at coaxial output |
| EFT/Burst: Polarity | Pos / neg / alternate |
| EFT/Burst: Output Impedance | 50 Ohm |
| EFT/Burst: Rise Time | 5 ns ±30% |
| EFT/Burst: Impulse Duration |
50 ns ±30% at 50 Ohm |
| EFT/Burst: Burst Mode | Normal, continuous, real, random |
| EFT/Burst: Spike Frequency | 1 Hz–1 MHz |
| EFT/Burst: Burst Duration | 10 µs–1 s |
| EFT/Burst: Burst Period | 1 ms–10 s |
| EFT/Burst: Test Time | 1 s–1,000 minutes, infinite |
| EFT/Burst: Trigger | Automatic, manual, external trigger input |
| EFT/Burst: Integrated single phase CDN | 264 V AC / 16 A up to 220 V DC / 10 A |
| Surge Combination Wave: Output Voltage | 0.2–5.0 kV ±10% |
| Surge Combination Wave: Voltage Rise Time | 1.2 µs ±30% |
| Surge Wave Combination: Voltage Duration | 50 µs ±20% |
| Surge Combination Wave: Polarity | Postive / negative / alternate |
| Surge Combination Wave: Output Impedance | 2 Ohm |
| Surge Combination Wave: Phase Sync | 0–359° with 1° steps or asynchronous mode |
| Surge Combination Wave: Counter Preselect | 1–1,000 / infinite |
| Surge Combination Wave: Counter | 100000 |
| Surge Combination Wave: Peak Voltage Monitor | BNC output: 1000:1 display: 3 digits |
| Surge Combination Wave: Output Current | 0.1–2.5 kA ±10% |
| Surge Combination Wave: Current Rise Time | 8 µs ±20% |
| Surge Combination Wave: Current Duration | 20 µs ±20% |
| Surge Combination Wave: Integrated Single Phase CND | 264 V AC / 16 A up to 220 V DC / 10 A |
| Surge Combination Wave: Impulse Trigger | Automatic 2 s - 100 min manual external trigger input |
| Surge Combination Wave: Peak Current Monitor | BNC output: 1 kA/V display: 3 digits |
| DIPS & Interrupts: Max. Voltage | 264 V AC/DC |
| DIPS & Interrupts: Max. Current |
16 A AC/DC continuous |
| DIPS & Interrupts: Trigger | Automatic, manual, external |
| DIPS & Interrupts: Dip Level |
0% |
| DIPS & Interrupts: RMS Voltage Monitor | BNC output: 100:1 display: 3 digits |
| DIPS & Interrupts: Interrupt Time |
0.5 period – 800 periods |
| DIPS & Interrupts: Interval Time |
1 period – 800 periods |
| DIPS & Interrupts: Test Time | 1 s–1000 minutes, infinite |
| DIPS & Interrupts: Phase Sync | 0–359°, 50 / 60 Hz, external, asynchronous mode |
| DIPS & Interrupts: RMS Current Monitor | BNC output: 10 A/V display: 3 digits |
| Attribute | Value |
|---|---|
| Data Sheet | Click here to view |