27560304
27560304
LAPP Cable
Safety cable with central loose tube, LSZH inner and outer sheath, corrugated steel tape; halogen-free
HITRONIC® FIRE- A/J-DQ(ZN)BH(SR)H- security cable with central loose tube, inner and outer sheath, corrugated steel tape, with single-mode or multimode fibres
Contact us for Lead Time
Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.
27560304 Specifications
- Central loose tube with up to 24 fibres
- Colour-coded fibres
- Longitudinal watertight
- Outer sheath flame-retardant and halogen-free
| Attribute | Value |
|---|---|
| Product Brand Name | HITRONIC® FIRE 4G 50/125 OM3 |
| Extended Description |
Benefits
|
| Benefits | Ensures that the fibres can still transmit data during and after a fire (according to IEC 60331-25) | Suitable for installation in underground tunnels where fire safety is critical | Additional sheath protects the fibres for use in harsh environments | Armouring provides excellent protection against high mechanical stress and rodents | UV-resistant | longitudinally and laterally watertight |
| Manufacturer | Lapp |
| Fibre Type | 50/125 OM3 |
| Halogen free | Yes |
| UV Resistant | Yes |
| Heat Resistant | Yes |
| Number of fibres | 4 |
| Outer Diameter (mm) | 9.6 |
| Core Identification Code | Fibre colour code see data sheet |
| Permissible tensile force | Fixed installation: 1500 N | Short-term: 2200 N |
| Permissible tensile force HTML |
|
| Optical fibre type | Core material: glass | Cladding material: glass |
| Optical fibre type HTML |
|
| Benefits |
|
| Product Make Up |
|
| Product Make Up | Gel-filled loose tube | Water-blocking reinforced glass yarn strain relief | Corrugated steel tape armour | LSZH inner and outer sheaths | Colour: black (RAL 9005) |
| Core Identification Code HTML |
|
| Minimum Bending Radius | Static: ≥ 15 x outer diameter | Dynamic: ≥ 20 x outer diameter |
| Minimum Bending Radius |
|
| Temperature Range |
|
| Technical Data |
Core identification code
|
| Applications |
|
| Weight kg per km | 123 |
| Temperature Range | Fixed installation: -30°C to +70°C |
| Applications | In industrial areas that use fire as a tool | Highly combustible or fire-prone areas | For indoor and outdoor use | Methods of Deployment: empty plastic pipes, ducts and trays |
| Features | Central loose tube with up to 24 fibres | Colour-coded fibres | Longitudinal watertight | Outer sheath flame-retardant and halogen-free |
| Attribute | Value |
|---|---|
| Data Sheet | Click here to view |