30017787

30017787

30017787

LAPP Cable

Halogen-free installation cable in accordance with DIN VDE 0815

J-H(ST)H...BD - telecommunication installation cable, solid conductor/ stationary use, star quads, static foil, halogen-free/ highly flame retardant, VDE 0815
Contact us for lead time

Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.

More Information
Attribute Value
Product Brand Name J-H(ST)H...BD
Approvals
  • In accordance with DIN VDE 0815type J-H(ST)H...BD
Extended Description Benefits
  • Used to meet enhanced fire protection requirements concerning protection of people and high-value property
  • Does not emit any toxic or corrosive gases in the event of fire and resists the spread of fire
  • Aluminium-laminated plastic foil static screen with tin-plated drain wire minimises the interference of high frequency, electromagnetic fields
  • Decoupling of circuits by means of twisted-pair (TP) design (crosstalk effects)
  • J-H(ST)H...BD Fire Alarm Cable is marked with the phrase "Fire alarm cable” at regular intervals on the sheath. It is therefore used especially for installation in fire alarm systems.
Applications
  • This halogen-free, flame-retardant cable with static shielding is made for stationary use for telephone, data and signal transmission in subscriber stations and private branch exchange construction for telephone systems
  • For fixed installation on and under plaster, in dry and damp rooms
Features
  • Flame retardant acc. to DIN VDE 0472-804/08.83, Test method C
  • Halogen-free according to EN 50267-2-1/-2
Product make up
  • Solid bare copper conductor
  • Core insulation made of special halogen-free compound
  • Cores twisted into star quads, 5 star quads are twisted into a bundle, bundles stranded in layers
  • Foil wrapping
  • static screening made of aluminium-laminated plastic film with copper drain wire
  • Outer sheath made of special halogen-free compound
  • Outer sheath colour: grey (RAL 7001)
Halogen free Yes
Flame Retardant Yes
Interference rejecting Yes
Number of conductors 2X2
mm2 per conductor 0.8
Outer Diameter (mm) 7
Copper index kg per km 25.0000
Conductor resistance HTML
  • 0.6 mm: max. 130 ohm/km
  • 0.8 mm: max. 73.2 ohm/km
Technical Data Core identification code
  • according to VDE 0815
Conductor stranding
  • 0.6 mm: 0.28 mm²
  • 0.8 mm: 0.50 mm²
Minimum bending radius
  • Fixed installation: 8 x outer diameter
Test voltage
  • Core/core: 800 V
  • Core/screen: 800 V
Conductor resistance
  • 0.6 mm: max. 130 ohm/km
  • 0.8 mm: max. 73.2 ohm/km
Temperature range
  • Occasional flexing: -5°C to +50°C
  • Fixed installation: -30°C to +70°C
Weight kg per km 77.0000
More Information
Attribute Value
Data Sheet Click here to view

Related Products

  1. 0037120
  2. 1032011
  3. 0031322
  4. 0032304
  5. 0034625