Attribute Value
Product Brand Name NYY-J
Approvals
  • HD 603/VDE 0276-603 (for 1 to 5 cores)
  • HD 627/VDE 0276-627 (as from 7 cores)
Extended Description Applications
  • For indoor and outdoor use
  • Burial without additional, suitable underground protection according to VDE standard HD 603/VDE 0276-603 - Part 3-G (point 4) governing PVC cables for direct burial: normal minimum installation depth 0.6 m, but at least 0.8 m under roads
  • In concrete with a temperature below the maximum cable operating temperature of +70 °C according to the VDE standard HD 603/VDE 0276-603 - Part 3-G (point 4) governing PVC cables for direct burial
Features
  • Flame-retardant according IEC 60332-1-2
  • Current rating according to HD 603/VDE 0276-603, Part 3-G, Table 14 (buried at +20 °C ground temperature according to HD 603/VDE 0276-603, Part 3-G, point 5) for routing underground and Table 15 (in the air at an air temperature of +30 °C according to HD 603/VDE 0276-603, Part 3-G, point 5) when used outdoors; but always taking into consideration corrections/reductions to the current rating that may be necessary according to VDE 0298-4, and VDE 0298-4 (also refer to the catalogue appendix T12) for installation in and on buildings
  • Maximum DC voltage to ground 1,8 kV according to HD 603 / DIN VDE 0276-603
Product make up
  • Bare copper wire conductor
  • Core insulation: Based on PVC
  • Filling compound over the core assembly
  • Outer sheath: Based on PVC
Manufacturer Lapp
Outdoor Use Yes
Number of conductors 24
mm2 per conductor 1.5
Protective Conductor No
Outer Diameter (mm) 24
Copper index kg per km 346.0000
Technical Data Core identification code
  • Up to 5 cores: colour-coded according to VDE 0293-308, refer to Appendix T9
  • From 6 cores: black with white numbers
Conductor stranding
  • Single or multi-wire
Minimum bending radius
  • Single-core: 15 x outer diameter
  • Multi-core: 12 x outer diameter
Nominal voltage
  • U0/U: 0.6/1.0 kV
Test voltage
  • 4000 V
Temperature range
  • During installation: -5°C to +50°C
  • Fixed installation: -40°C to +70°C
Weight kg per km 900.0000