LAPP Cable

Industrial Ethernet cable Cat.6A for torsion stress applications

Industrial Ethernet cable Cat.6A for torsion stress applications (± 180°);4 pairs, PVC or PUR jacket with UL approval, design 4x2xAWG24/7, for PROFINET Type C
Contact us for lead time

Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.

More Information
Attribute Value
Product Brand Name ETHERLINE® TORSION Y CAT6A
Approvals
  • electrical requirements acc. to IEC 61156-6
  • PUR cable is UL/CSA-certified (CMX)
  • PUR versions: UL AWM Style 21576
  • PVC cable is UL/CSA-certified (CM)
  • Flame retardant acc. to IEC 60332-1-2
Extended Description Benefits
  • Many applications with Industrial Ethernet, e.g. PROFINET, i.e. fixed installation, flexible use as well as TORSION.
  • 4pair: 100Mbit/s up to 10 Gbit/s for Industrial Ethernet
  • Premium screening against electromagnetic interference
  • Can be used for Industrial Ethernet in harsh industrial environments
Applications
  • Suitable for torsional applications which are typical for the loop in wind turbine generators (WTG)
  • Can be used for Industrial Ethernet in harsh industrial environments
  • suitable for EtherCAT and EtherNet/IP applications
Features
  • PUR version is halogen-free according to VDE 0472-815
  • Oil-resistant acc. IEC 60811-2-1
  • Cable suitable for high torsion stress. Tested with more than 1 million bending cycles and a right/left movement of 180° per metre.
  • Meets the requirements according to CAT.6A, ISO/IEC 11801 and EN 50173
Product make up
  • 7-wire tinned stranded copper conductor
  • Core insulation made of polyethylene (PE)
  • S/FTP: copper braid as overall screening and pair screening with aluminium compound foil
  • Outer sheath: PUR/PVC
  • Colour: green (based on RAL 6018)
Outdoor Use Yes
UV Resistant Yes
Interference rejecting Yes
Number of conductors 4x2
AWG per Conductor 24
Outer Diameter (mm) 8.9
Copper index kg per km 44.0000
Technical Data Minimum bending radius
  • Fixed installation: 8 x cable diameter
  • Flexing: 15 x outer diameter
Characteristic impedence
  • nom. 100 Ω acc. to IEC 61156-6
Temperature range
  • Fixed installation: -40°C to +80°C
  • Flexing: -10°C bis +70°C
Weight kg per km 88.0000