The voltage of the solar installations (also known as photovoltaic or PV installations) increases to reduce cost and improve the efficiency of solar equipment. As a result, it is important to select measuring instruments that support higher voltage measurement to protect the safety of inspection workers.
The P2000 enables high voltage measurement up to CAT III 2000 V by simply connecting to a compatible Hioki clamp meter or digital multimeter (DMM).
Contact us for lead time
Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.
Enables high voltage measurement up to CAT Ⅲ 2000 V
Safely measure solar installations like the mega-solar without interrupting the grid
Connects to compatible Hioki clamp meters and digital multimeters (DMMs)
Basic Specifications
Maximum input voltage (*1)
DC 2000 V
Maximum rated line-to-ground voltage
1000 V (Measurement Category IV), Anticipated transient overvoltage 12000 V
2000 V (Measurement Category III), Anticipated transient overvoltage 15000 V
Input resistance
20 MΩ ±5.0% (between INPUT H and INPUT L, when OUTPUT terminal is open)
Overload protection
2200 V DC/2200 V AC (applied for 1 minute) (between INPUT H and INPUT L)
600 V DC/600 V AC (applied for 1 minute) (between OUTPUT H and OUTPUT L)
OUTPUT terminal
4 mm banana terminal
Operating temperature and humidity range
Temperature:
-25°C to 65°C (-13°F to 149°F)
Humidity:
−25°C to 40°C (−13°F to 104°F): 80% RH or less (non-condensing)
40°C to 65°C (104°F to 149°F): Linearly reduces from 80% RH or less at 40°C (104°F) to 25% RH or less at 65°C (149°F) (non-condensing)
Storage temperature and humidity range
-30°C to 70°C (-22°F to 158°F) 90% RH or less (non-condensing)
Standards
EN 61010
Included accessories
Connection Cable Set L4943 ×1, Strap with buckle ×2, Strap ×1, Carrying Case C0205 ×1, Instruction Manual ×1, Operating Precautions ×1