RAD H2O
RAD H2O
Durridge
Radon in Water Sampling
The RAD H2O is an accessory for the RAD8 and RAD7 that enables you to measure radon in water over a concentration range of from less than 10 pCi/L to greater than 400,000 pCi/L. By diluting your sample, or by waiting for sample decay, you can extend the upper range to any concentration.
The equipment is portable and battery-operated, and the measurement is fast. You can have an accurate reading of radon in water within an hour of taking the sample. The RAD H2O gives results after 30 minutes analysis with a sensitivity that matches or exceeds that of liquid scintillation methods. The method is simple and straightforward. There are no harmful chemicals to use. Once the procedure becomes familiar and well understood it will produce accurate results with minimal effort.
By taking two simultaneous samples, analysing one immediately, waiting a week or more and then analysing the other, the radium (226Ra) content of the water may be calculated.
Key Features
- Portable: Complete kit provided in fitted case; weighs just 13 lbs.
- Automatic: The procedure is controlled fully by the connected RAD7. Printouts provide data on radon concentration in water.
- Fast: Analysis can be completed within one hour of taking the water sample.
- Accurate: The RAD H2O provides results as accurate as liquid scintillation.
- Sensitive: More sensitive than liquid scintillation. The lowest limit of detection is 10 pCi/L (20-minute count).
- Clean and Safe: Involves no hazardous materials or chemicals.
- Proven: Used by individuals and labs throughout the world for over ten years.
- Great Value: Practically no running costs.
Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.
Attribute | Value |
---|---|
Dimensions |
RAD H2O Shipping Dimensions: 19″ x 16″ x 8″ (48 cm x 41 cm x 20 cm) |
Configuration | A vial containing a water sample is set up in a closed air loop with the RAD8 or RAD7 radon detector. The pump in the radon detector operates automatically for five minutes to aerate the sample, distributing the radon that was in the water throughout the loop. The radon detector waits a further five minutes while the 218Po count rate approaches equilibrium and then counts for four five-minute cycles. The radon concentration in the water is calculated directly. |
Comes With | The complete RAD H2O consists of the RAD H2O Case package, RAD H2O Aerator Cap Kit, RAD H2O Glass Frit Kit, Indoor Faucet Adaptor, and RAD H2O Tubing Set. |
Attribute | Value |
---|---|
Data Sheet | Click here to view |