7224RLY
7224RLY
AE Techron
For Protection Relay Production Testing and Commissioning
Up to 52 Ap Current Source
- High compliance voltage allows the 7224RLY to drive electromechanical relays directly
- Maintains phase accuracy for any load from a dead short to 2 ohms
- Front panel indicators for rapid assessment of amplifier status
- Protection circuitry protects from input overloads, improper output connection (including shorted and improper loads), over-temperature, over-current, and supply voltages that are too high or low
The 7224RLYwas created to meet the demanding requirements of the power utility industry. Capable of outputting a 40 mSec pulse with up to 52 amperes peak current, the 7224RLY is powerful enough to put protection relays, fuses and other critical components through a full range of tests.
The low noise floor, low distortion and minimal phase error of the 7224RLY make it the ideal amplifier for power grid modeling.
Key Performance Capabilities:
- Up to 50 Ap (35A RMS) output power at 0.5 ohms
- Up to 158 Vp output voltage
- Standard transconductance of 20 ±0.2% from short to 1-ohm load
- Residual noise of less than 2.5 mA peak, from 40 Hz to 600 Hz
Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.
Attribute | Value |
---|---|
Protection |
Over/Under Voltage: ± 10% from specified supply voltage amplifier is forced to Standby Over Current: Breaker protection on both main power and low voltage supplies Over Temperature: Separate output transistor, heat sink, and transformer temperature monitoring and protection |
Physical Characteristics |
Chassis: The amplifier is designed for stand-alone or rack-mounted operation. The chassis is black aluminum with a powder coat finish. The unit occupies two EIA 19-inch-wide units. Weight: 41 lbs (18.6 kg), Shipping: 51 lbs (23.2 kg) AC Power: Single phase, 120 VAC, 60 Hz, 10 Amp service; (220-240 VAC, 50-60 Hz, 10 Amp service model available) Operating Temperature: 10°C to 50°C (50°F to 122°F), maximum output Power de-rated above 30°C (86°F). Humidity: 70% or less, non-condensing Cooling: Forced air cooling from front to back through removable filters. Airflow: 180CFM Dimensions (HxWxD): 3.5” x 19” x 22.75” (8.9 cm x 48.3 cm x 57.8 cm) |
Bandwidth | DC to 10 kHz |
Status Display, Control, I/O |
Front Panel LED Displays indicate: Ready, Standby, Fault, Over Temp, Over Voltage, Overload Soft Touch Switches for: Run, Stop, Reset Gain Control, when enabled: Voltage gain adjustable from 20 to 0 On/Off Breaker Back Panel Power Connection: 25 Amp IEC (with retention latch) Signal Output: Three-position terminal strip (OUTPUT/COM/CHASSIS GROUND) Signal Input: User-selectable BNC or barrier strip; balanced or unbalanced |
Communication Capabilities |
Current Monitor: 5A/V ± 1%; 2.5A/V ± 1% (differential configuration) Reporting: System Fault, Over Temp, Over Voltage, Over Load Remote Control via Interlock Connector: Force to Standby, Reset after a fault |
Residual Noise | Less than 2.5 mA peak |
Unit to Unit Phase Error | ±0.1 degrees |
Maximum Output Voltage | 158 Vp |
Load Constraint for Maximum Output | 0.5 ohms + 200 mH |
Output Offset Current | Less than 10.0 mA DC peak |
Standard Transconductance | 20 ±0.2% |
Common Mode Rejection Ratio | -58 dB minimum |
Input-to-Output Phase Delay | -0.2 degrees |
Out Accuracy | Less than ±1% |
Maximum Output Current | 35A RMS (50 Ap) |
Input Characteristics |
Balanced with ground: Three terminal barrier block connector, 20k ohm differential Unbalanced: BNC connector, 10k ohm single ended Gain, Voltage Mode: 20 volts/volt; Current Mode: 20 amperes/volt Gain Linearity (over input signal, from 0.2V to 5V):
Max Input Voltage: ±10V, balanced or unbalanced Input Impedance: 20 k ohm; differential Input Sensitivity: 3.0V input for 3800W output into 1 ohm (adjustable) Common Mode Rejection Range: -±11 VDC maximum Common Mode Rejection Ratio: Better than -65 dB
|
Attribute | Value |
---|---|
Data Sheet | Click here to view |