VEBOS
VEBOS
ELSE NUCLEAR
Whole Body In-Vivo Counting System
The VEBOS system is designed to perform a complete scan of individuals standing in front of a vertically moving detection equipment.
The measuring equipment is composed of 2 liquid-nitrogen-cooled HPGe detectors, each coupled to a 30 l nitrogen dewar, and managed by a multi-channel analyser.
The detectors are shielded with lead collimators in order to reduce the contribution due to environmental background. The collimators can also be used to define a detection field of view, according to the measurement requirements (e.g. full body scan, hot spot deep analysis, etc.).
The detectors and related components are lodged on a mechanically moving shelf, activated by the system software according to the pre-set measurement sequence.
The mechanical structure of VEBOS includes a main frame which acts both as supporting structure as well as shielding from external background contribution.
The primary user interface is provided by a built-in panel PC with proprietary software allowing the complete management of the system, i.e. activation and control of the measurements, display/archive of the results, etc.
Several safety devices are implemented in VEBOS: a base platform that detects an individual presence, interlocks at the maintenance door, and buttons on the holding handles to enable the movement of the detectors.
Key Features
- Measure of total body activity and committed effective dose
- Fully automatic scanning system
- Alternative detection equipment options
- Detectors: two liquid-nitrogen-cooled HPGe
- Low-background lead shielding/collimators
- Extensive safety devices
- Several operating modes available according to required activities
- Alarm column
- Handles for helping the person to keep a suitable position during measurements
- Door for easy access to the detectors for maintenance activities
- Eyebolts for easy deployment of the system
Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.
Attribute | Value |
---|---|
Energy Range | 40 KeV - 10 MeV |
Dimensions | 2000 x 2720 x 1800mm (W x H x D) |
Options |
Alternative detection equipment options, e.g.: liquid-nitrogen-cooled HPGe detectors, NaI(Tl) scintillators, etc. |
Accessories | BOMAB phantom for calibration |
Detection Unit |
Detector type: electro-cooled coaxial P-type HPGe detectors or NaI(Tl) scintillators Number of units: 2 Lead shielding/collimator thickness: 50 mm Relative efficiency: ≥ 25% Energy resolution (122 keV): 0.82 keV Energy resolution (1.33 MeV): 1.85 keV Peak to Compton: 56:1 Detectors endcap size: 70 mm |