Meinberg LANTIME M320 | APC Technology Group

LANTIME M320

LANTIME M320

Meinberg

NTP Time Server in a 1U Case for Server Rackmounting

The Meinberg LANTIME M320 time server is used to provide highly accurate time to networks of all sizes. They synchronise all systems that are either NTP or SNTP compatible. As a reference time source, this NTP system typically uses a built-in Meinberg reference clock or a compatible external time source (operating in stratum 1 mode). Up to 7 external NTP servers can also be set as time reference (operation as stratum 2 server).

A large display shows the state of the NTP subsystem.

Because of its modular system architecture, it is possible to equip this LANTIME time server with up to six ethernet ports, even fiber optic network ports and one or three Gigabit Ethernet ports are available as an option.

Oscillator Option

The LANTIME M320is shipped as standard with a “TCXO” (temperature-controlled crystal oscillator), which provides excellent holdover performance if your server loses synchronisation with its upstream reference for any reason. The LANTIME M320 may also be shipped on request with a more powerful holdover solution (OCXO LQ/SQ/MQ/HQ). Please speak with a member of APC's specialist time synchronisation team for further information.

MRS - Multi Reference Source capable

In addition, this NTP time server can also be synchronised via other signal sources such as GNSS or NTP. PPS, 10 MHz, IRIG Time Codes are also available for our M320/MRS model.

The MRS version comes with a high-quality OXCO and is designed to act as a reliable time source in applications where no antenna can be installed. The internal OCXO-HQ can be fully disciplined by utilising one or more remote NTP time servers. Thus, a LANTIME MRS time server can be run in a fully independent mode in environments where no source of time is available.

Configuration and Monitoring

The configuration of the system can be managed by using a standard web browser for accessing the extensive but straightforward HTML web interface. Alternatively, a text-based and menu-driven setup utility can be started from the shell prompt after logging into the unit via Telnet or SSH.

Contact us for lead time

Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.

More Information
Attribute Value
Manual URL https://www.meinbergglobal.com/download/docs/manuals/english/setup-guide_d.pdf
Technical Support Meinberg offers free lifetime technical support via telephone or e-mail. Additonaly, APC's own team of time synchronisation specialists are available for first line technical support.
Form Factor 19 inch multipac metal case 1U/84HE
Relative Humidity Max. 85%
RoHS Yes
Control elements Eight push buttons to set up basic network parameters and to change receiver settings
Status info

Four Bicolor LEDs showing the status of:

  • Reference time
  • Time service
  • Network
  • Alarm
Frequency Outputs

10 MHz via female BNC connector, TTL into 50 Ohm
Accuracy depends on the oscillator (standard: TCXO)

Pulse outputs Pulse Per Second (PPS), TTL level, pulse width: 200 ms
Accuracy of Pulse Outputs

Depends on oscillator option:

  • < ±100ns (TCXO, OCXO LQ)
  • < ±50ns (OCXO SQ, OCXO MQ, OCXO HQ, OCXO DHQ)
Network Interface

Standard: 2 x 10/100 MBit with RJ45 connector

Available Options:

  • 2 or 4 x additional 10/100 MBit with RJ45
  • 2 additional 100 MBit with fibre optic SC connector, duplex
  • 1 x 10/100 MBit and 1 x 10/100/1000 MBit with RJ45 or:
    1 x 10/100 MBit and 3 x 10/100/1000 MBit with RJ45 jack
Universal Serial Bus (USB) Ports

1 x USB port on the front panel for:

  • Installing firmware upgrades
  • Performing backups and restoration of configuration files
  • Copying security keys
  • Locking & unlocking front buttons
Data format of interfaces

COM 0:

  • Baudrate: 300, 600, 1200, 2400, 4800, 9600, 19200 Baud
  • Data Format: 8E1, 8E2, 8N1, 8N2, 8O1, 7E1, 7E2, 7N2, 7O1, 7O2
  • Time Telegram: Meinberg Standard-Telegram , SAT, NMEA RMC, Uni Erlangen (NTP), COMPUTIME, Sysplex, Capture-Telegramm, SPA, RACAL, Meinberg GPS, NMEA GGA, NMEA RMC GGA, NMEA ZDA, ION, 6021 or IRIG-J
CPU
  • Intel® Atom™ Processor E Series (2 Cores, 1.33GHz, TDP 3W)
  • Main memory: onboard 2 GB
  • Cache memory: 1MB 2nd Level Cache
  • Flash disk: 4 GB
Operating System of the SBC Custom LANTIME OS based on Linux 4.x LTS Kernel
Network protocols OSI Layer 4 (transport layer)
  • TCP
  • UDP
Network protocols OSI Layer 7 (application layer)
  • Telnet
  • FTP
  • SSH (including SFTP, SCP)
  • HTTP
  • HTTPS
  • syslog
  • SNMP
Internet Protocol (IP)
  • IPv4
  • IPv6
Network Autoconfiguration Support
  • IPv4: Dynamic Host Configuration Protocol - DHCP (RFC 2131)
  • IPv6: Dynamic Host Configuration Protocol - DHCPv6 (RFC 3315) and Autoconfiguration
  • Networking - AUTOCONF (RFC 2462)
Network Time Protocol (NTP)
  • NTP v2 (RFC 1119), NTP v3 (RFC 1305), NTP v4 (RFC 5905)
  • SNTP v3 (RFC 1769), SNTP v4 (RFC 4330)
  • MD5 / SHA-1 authentication and autokey key management
Parallel Redundancy Protocol (PRP) PRP (IEC 62439-3)
Time Protocol (TIME) Time Protocol (RFC 868)
IEC 61850 Synchronisation of IEC 61850-compliant devices using SNTP
Hypertext Transfer Protocol (HTTP) HTTP(S) for web interface and REST API access
Secure Shell (SSH)
  • SSH v1.3
  • SSH v1.5
  • SSH v2 (OpenSSH)
Telnet Telnet (RFC 854-RFC 861)
Scope of supply Included in delivery is a Meinberg outdoor antenna incl. mounting kit, pre-assembled antenna cable, CAB-CONSOLE-RJ45 cable for initial setup and documentation on USB storage.
Firmware Updates Firmware is field-upgradeable, updates can be installed directly from the unit or via a remote network connection. Software updates are provided free of charge for the lifetime of your Meinberg product.
WEEE status of the product This product is handled as a B2B category product. For disposal, it must be returned to the manufacturer to ensure WEEE compliance. Any transportation expenses for returning this product (at end-of-life) must be covered by the end user, while Meinberg will cover the costs for the waste disposal itself
Supported PTP Profiles
  • SNMPv1 (RFC 1157)
  • SNMPv2c (RFC 1901-1908)
  • SNMP v3 (RFC 3411-3418)
Optional Output Signals

Additional Output Options:

This LANTIME NTP server comes with many additional outputs options: PPS, 10MHz, programmable pulse outputs (PPS, PPM, PPH, DCF_MARK ...), IRIG modulated and unmodulated time code, T1 / E1 telecom signals, Frequency Synthesizer - to name just a few. Contact us for your specific device configuration.

Key Features
  • Selectable Reference Sources:
    • GPS: Satellite receiver for the Global Positioning System
    • GNS: Combined GPS/GLONASS/Galileo/BeiDou satellite receiver (L1 frequency band), can also be used for mobile applications
    • GNS-UC: GPS and Galileo satellite receiver with up-converter for Meinberg GPS antenna/converter
    • PZF: DCF77 correlation receiver for middle Europe
    • MSF: Long wave recevier for Great Britain
    • TCR: Time code receiver for IRIG A/B, AFNOR or IEEE1344 codes
    • MRS: (GPS, PPS, 10MHz, NTP): Multi Reference Source - several reference sources, adjustable following priority of signal
    • RDT: (external PPS or NTP): Time Server without internal receiver module

  • Synchronises NTP-compatible clients with support for NTP, SNTP, and NTS
  • Web interface that is both powerful and easy to use
  • Backlit LCD panel and function keys for local configuration
  • Comprehensive networking support, including full HTTPS encryption for Web Interface and REST API with TLS certificate management
  • Frequency signals and industry-specific sync signals via additional optional outputs
  • USB port for installation of firmware updates, backup/restore of configuration and log files, and disabling/enabling access to front panel controls
  • Command line interface for advanced power users with absolute control over every facet of the server's functionality
  • Support for syslog, SNMP, and SMTP for comprehensive event logging, network integration, and notification functionality
  • GNS models include Multi-GNSS antenna for reception of GPS, Galileo, BeiDou, and GLONASS signals
  • GPS and GNS-UC models include Meinberg IF antenna of reception of GPS signals and, with GNS-UC models, also Galileo signals
Operating Temperature 0 - 50°C
Interface Two independent serial RS-232 interfaces, menu configurable (in case of RDT models without internal receiver - the serial interfaces will be used as reference input).
Power Supply

Standard:

100-240 V AC (50-60 Hz) / 100-240 V DC

Available DC variants:

100-200 V DC, 24 V DC and 24-48 V DC

Redundant power supply combinations are also available.

Dimensions 443 x 288 x 45
Display LC-Display, 2 x 40 Characters, with Backlight
More Information
Attribute Value
Data Sheet Click here to view

Related Products

  1. LANTIME M400
  2. LCES
  3. LANTIME M150
  4. LANTIME M300
  5. SyncFire