SH-60S-TC
SH-60S-TC
Bird
Handheld Spectrum Analyzer
The SH-60S-TC provides real-time spectrum monitoring and analysis of RF frequency circuits with a wide frequency range of between 9kHz to 6 GHz. Our analyzer has been developed for field engineers, technicians, wireless equipment manufacturers, service providers, contractors, tower erectors and military field personnel.
Bird combines best-in-class functionality with compact package and boasts an intuitive touchscreen user interface. SH-60S-TC let’s you experience high performance and rich features that are available wherever you take it.
Signal bursts and transients can be viewed using the “Zero-span” function with video-level triggering (i.e. an oscilloscope with time on the x-axis) or “Waterfall” display (color-coded scrolling chart display) to analyze intermittent signal sources.
Contact us for lead time
Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.
SH-60S-TC Specifications
- Spectrogram/Waterfall display shows intermittent power levels at a glance.
- FM demodulation allows for rapid verification of communications at the specified frequency.
- Predefined measurements scan and discover spectrum events other analyzers miss.
- View the spectrum with trace display, spectrogram display, or both.
- Easy-to-use, intuitive menus with multi-touch operation.
- More than 2x faster sweep times than the competition.
- High-resolution, full-color display for indoor or outdoor viewing.
- Rugged and weather resistant.
- 5 hours of continuous battery operation.
- Includes the Bird RF Meter App for interoperability with a wide range of Bird Field sensors.
Attribute | Value |
---|---|
Product Brand Name | Hand-Held Spectrum Analyzer |
Manufacturer | Bird |
Video URL | https://youtu.be/Nf9OWQt5bH8 |
Languages | English, Chinese |
Standard Accessories | Hard Carrying Case, Soft Carrying Case, AC Adapter (12 Vdc Ouput), Stylus, USB Drive, USB Adapter, Manual and Battery |
Frequency Range | Range: 9 kHz to 6 GHz, Span Accuracy: ±1% |
Predefined Measurements |
|
Aging | ±1 ppm |
Sweep Time | 1.1 ms to 1600 s Full Span, 2.69 ms to 1600 s Settable Zero Span |
Resolution Bandwidth | 10 Hz to 5 MHz in 1, 2, 3, 5, 10 Steps, Accuracy: ≥1 MHz, ±10% (<1 MHz, ±2%) |
Second Harmonic Distortion | 1.6 GHz -70 dBc |
Third Order Intercept | +15 dBm (–10 dBm tones , 1 MHz apart, Preamp Off, Reference Level –10 dBm) |
Phase Noise | -95 dBc/Hz,@10 kHz (typical -97 dBc/Hz), -115 dBc/Hz,@1 MHz (typical -116 dBc/Hz) |
Measurement Range | DANL to +20 dBm |
Input Attenuator | Range: 0 to 30 dB, 1 dB step, Uncertainty: ±0.6 dB |
Max Safe Input Level | Preamp Off: +30 dBm, Preamp -20 dB: 0 dBm, Preamp +40 dB: -20 dBm |
RBW Switching Uncertainty | ±0.3 dB |
Display Average Noise Level | Preamp Off: 1 GHz, -129 dBm/Hz (typical -132 dBm/Hz), Preamp +20 dB: 1 GHz, -149 dBm/Hz (typical -152 dBm/Hz), Preamp +40 dB: 1 GHz, -168 dBm/Hz (typical -169 dBm/Hz), (Input terminated, Detector set to Positive, Trace Average set to 1000, Span set to 50 kHz, Reference level of -100 dBm, all other settings auto-coupled, 23±5 °C normalized to 1 Hz RBW) |
Residual Responses | -75 dBm |
Amplitude Accuracy | ±1.5 dB (ATT set to 0 dB , input signal -5 to -30 dBm, Detector set to Positive, Sensitivity set to Low, RBW auto-coupled, all other settings auto-coupled, 23±5 °C. Half hour warm-up required.) |
Reference Level Accuracy | ≥ -60 dBm, ±0.8 dB |
Operating System | Android |
P1dB | +5 dBm (nom) |
Display Type | 5.5 inch, 1280 x 720 pixel |
Connectors | RF In: N (Female), USB: USB type C, Power Interface: Slim Tip, DC 20V |
Battery | Type: Li-ion, Operating Time: 5 hours (typ), Charge Time: 6 hours (typ) |
Temperature Range | Operating: 0 to 50°C, Storage: -20 to 70°C |
Dimensions | 7.8" x 3.7" x 2.4" (197 x 93 x 61 mm) |
Attribute | Value |
---|---|
Data Sheet | Click here to view |