CT6711
CT6711
Hioki
Current Probe
Capture Inrush, Micro and High-Speed Currents with a Single Probe
Hioki flat bandwidth current probes are best-in-class current sensors for use with Memory HiCorders and high performance oscilloscopes. The CT6711 is a 3-range, high-sensitivity current probe that offers a wide DC to 120 MHz bandwidth and 200 μA to 30 A input, letting your capture signals across an expansive current range, from steady state to transient currents, when developing switching power supplies, inverters, and motor controllers.
Use with an instrument with a high input impedance of 1 MΩ or higher.
Key Features
-
3 ranges in a single probe - 30 A, 5 A, 0.5 A. Observe a wide current range from micro currents to 30 A.
-
Wide band: DC to 120 MHz (-3 dB)
-
High S/N ratio and 10 times output rate: Observe waveforms at 100 μA/div at oscilloscope maximum voltage sensitivity setting of 1 mV/div
Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.
Attribute | Value |
---|---|
Included Accessories | Instruction manual ×1, Carrying case ×1 |
Max Allowable Input | 30 A range: ±50 A peak (within the input limit time 2 s) 5 A range: ± 7.5 A peak, 0.5 A range: ± 0.75 A peak (< 10 MHz), ±0.3 A peak (≥ 10 MHz) |
Dimensions and Weight | Sensor: 155 mm (6.10 in)W × 18 mm (0.71 in)H × 26 mm (1.02 in)D, Relay box section: 45 mm (1.77 in)W × 120 mm (4.72 in)H × 25 mm (0.98 in)D Terminator section: 29 mm (1.14 in)W × 83 mm (3.27 in)H × 40 mm (1.57 in)D mm, 370 g (13.1 oz) |
Basic Accuracy | 30 A range: ±3.0% rdg. ±1 mV, (Typical) ±1.0% rdg. ±1 mV (≤ 10 Arms, DC, 45 to 66 Hz sine wave, within the maximum peak current of each range) 5 A range: ±3.0% rdg. ±1 mV, (Typical) ±1.0% rdg. ±1 mV (DC, 45 to 66 Hz sine wave, within the maximum peak current of each range) 0.5 A range: ±3.0% rdg. ±10 mV, (Typical) ±1.0% rdg. ±10 mV (DC, 45 to 66 Hz sine wave, within the maximum peak current of each range) |
Measurement Terminals | φ 5 mm (0.20 in), Insulated conductor |
Rated Current | 30 A range: 30 A rms, 5 A range: 5 A rms, 0.5 A range: 0.5 A rms(DC, and sine wave, requires derating at frequency) |
Frequency Bandwidth | DC to 120 MHz (-3 dB) |
Output Voltage Rate | 30 A range: 0.1 V/A, 5 A range: 1 V/A, 0.5 A range: 10 V/A, (The output of this probe is internally terminated) |
Output Cable Length | Sensor cable (between relay box and sensor): 1.5 m (4.92 ft) Power cable: 1.0 m (3.28 ft) (Power plug: FFA.0S.304.CLAC37Y / LEMO inc.) |
Rise Time | 2.9 ns or shorter |
Delay Time | 30 A range: 12 ns, 5 A range: 12 ns, 0.5 A range: 13 ns (Delay time relative to rising waveform of input signal 1 ns) |
Noise Level | 75 μA rms max (at 0.5 A range, using 20 MHz band measuring instrument) |
Attribute | Value |
---|---|
Data Sheet | Click here to view |