Narda Safety Test Solutions 9010/30P, 10 Hz – 3 GHz

9010/30P

9010/30P

Narda Safety Test Solutions

Full/Pre Compliance Receivers

The 9010/30P receiver, is fully compliant in accordance with the CISPR 16-1-1 in the band A and B and pre compliance

Narda-PMM has developed new EMI / EMC receivers based on an innovative concept and a revolutionary approach to meet the needs of small and medium-sized laboratories that do not find it convenient to invest in a receiver conforming to the CISPR 16-1-1 also for radiated measurements.

They are a perfect mix of full and Pre-Compliance to meet, in a perfect way, the requirements of practical tests, not excluding the possibility of future upgrades to 100% Full-Compliant to CISPR 16-1-1 up to 3, 6 or 18 GHz the simple addition of an external unit, the receiver is connected via Fibre optic cable.

Receivers 9010/xxp are available in the following versions:

  • 9010/03P, 10 Hz – 300 MHz
  • 9010/30P, 10 Hz – 3 GHz
  • 9010/60P, 10 Hz – 6 GHz
Contact us for Lead Time

Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.

More Information
Attribute Value
Frequency Range

30 MHz to 3 GHz
Resolution, Freq. accuracy - 100 Hz, < 2 ppm

RF Input

RF Input: Zin 50 Ω, N fem.

VSWR 10 dB RF att.: < 1,2, < 2,0 over 1 GHz

0 dB RF att.: < 1,2, < 2,0 over 1 GHz

Attenuator: 0 dB to 50 dB (2dB steps)

Pulse limiter: n.a.

Preamplifier gain: n.a.

Max Input Level

Max input level: (without equipment damage)

Sinewave AC voltage: 137 dBμV (1 W)

Pulse spectral density: 97 dBμV/MHz

Preselector

Preselector: n.a.

IF Bandwidth

Standard 3/6 dB: (6 dB BW) 3, 10, 30, 100, 300 kHz, 1 MHz

CISPR-16-1-1: 120 kHz

MIL-STD-461 (option): 100 kHz, 1 MHz

Noise Level

30 MHz to 3 GHz < 8 dBμV (QP)

(120 kHz RBW) < 4 dBμV (AV)

Measuring Detectors Peak, Quasi-Peak, Average, RMS, RMS-Average(Optional), CISPR-Average, APD and Smart Detector function
Level Measuring Time

Peak, Quasi-Peak, AVG, RMS (simultaneous detectors):

1 ms to 30 s. (CISPR 16-1-1 default)

Display Units

dBm, dBμV (as stand-alone);
dBm, dBμV, dBμV/m, dBmA, dBmA/m, dBpW (through 9010 SW Utility on PC)

Spurious Response < 15 dBμV
Measurement Accuracy

30 MHz to 1 GHz ± 1,0 dB

S/N > 20 dB:

1 GHz to 3 GHz ± 1,5 dB

I/O Interface USB 2.0 (rear), USB 2.0 (front; only for future implementation), RS-232, high-speed optical link (2 channels; 2nd channel for future implementation), user port (for LISN connection, etc.), IEEE-488 (GPIB) optional
Operating Temperature 0 °C to 40 °C
Power Supply 10 - 15 Volt DC, 2,5 A; optional Li-ion interchangeable battery (8h use, typical)
Dimensions 235 x 105 x 335 mm
Weight 4.1 kg
Demodulation Built-in AM demodulator (headphone jack)
RF Output

RF output (tracking generator): Zout 50 Ω, BNC fem.
Frequency range: 10 Hz to 50 MHz
Level: 60 dBμV to 90 dBμV (0,1 dB steps)
Level accuracy: ± 0,5 dB (10 Hz to 30 MHz)

Dimensions 235 x 105 x 335 mm