Bird RF 5016D: Budget-Friendly Power Sensor for Field Use. Accurate, Wide Range (100MHz-3GHz). Available at APC, Bird RF Distributors. 0330 313 3220

5016D

5016D

Bird

25mW - 25W Avg, 60W Peak Wideband RF Power Sensor

25mW - 25W Avg, 60W Peak Wideband RF Power Sensor

The 5016D RF Power Sensor never requires field calibration, only requires calibration once per year and is traceable to the National Institute of Standards and Technology (NIST). The WPS measures True Average Power, Peak Power, and Duty Cycle directly with exceptional accuracy and uses these precise measurements to calculate a wide range of other important factors, such as VSWR, Return Loss, Reflection Coefficient, Crest Factor, Average Burst Power, and CCDF.

Included Accessories:

  • User Manual
  • VPM3 - Virtual Power Meter Software and Manual
  • 10 ft. USB Cable

Note:

The asterisk (*) displayed in the Product Specifications indicates (for temperatures above 35°C or below 15°C add 3.0% to stated accuracies) - this includes the entire "Accuracy-Peak Envelope Power" spec as well.

Contact us for lead time

Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.

More Information
Attribute Value
Manufacturer Bird
Certificates CE EMC EN 61326-1-2006
Impedance Ohm 50.0000
Accuracy - Peak Envelope Power burst width > 200 μs:  ± 7% of reading, + 0.05 W 1 μs < burst width < 200 μs:  ± 10% of reading, + 0.10 W 0.5 μs < burst width < 1 μs:  ± 15% of reading, + 0.10 W burst width < 0.5 μs:  ± 20% of reading, + 0.10 W
Average Power Average Forward Power Range:  25 mW to 25 Watts Avg, 60 Watts Peak *Accuracy, Average Forward Power:  ± 4% of reading, + 0.008 W Minimum Forward Power for Reflected Measurement:  0.1W Return Loss:  0.0 to 23 dB VSWR:  1.15 to 99.9
Burst Average Power Burst Average Forward Power Range:  .7 W to 25 Watts Avg Burst Width:  1 μs to 5 ms Repetition Rate:  5 Hz, Min Duty Cycle (D):  .002 to 1.0 *Accuracy, Burst Average Power:  ± 6% of reading, + 0.008 Watts
Complementary cumulative distribution function CCDF Measurement Range:  0.1 to 100% Threshold Measurement Range:  0.7 to 25 W Measurement Uncertainty:  ± 2% *Level Set Accuracy:  As Peak Envelope Power Accuracy + 2.0%
Crest factor Crest Factor Measurement Range:  25 mW to 25 Watts *Accuracy, Crest Factor:  Linear Sum of Peak and Average Power Accuracies
Directivity (dB) 30 dB up to 3.0 GHz 28 dB from 3.0 to 4.0 GHz
Frequency Range 350 MHz to 4.0 GHz
Insertion Loss <0.05 dB from 0.35 to 1.0 GHz <0.1 dB from 1 to 4 GHz
Insertion VSWR <1.05 from 0.35 to 2.5 GHz <1.10 from 2.5 to 4 GHz
Peak envelope power range 0.7 to 60 W
Power range 25 mW to 25 Watts Avg. 60 Watts Peak
Connectors N Female (Both)
Data logging Requires 5000-NG or VPM3
Temperature Range Operating -10 to +50 °C (+14 to +122 °F) Storage -40 °C to +80 °C (-40 °F to +176 °F)
Power Supply USB Port: less than one low-power USB load DC Input Connector: 7-18 VDC at less than 0.1A
Dimensions 4.8 in x 4.6 in x 1.3 in (122 mm x 117 mm x 33 mm)
Interface DPM Interface: DB9 proprietary interface, PC Interface (1): RS-232, 9600 Baud, no parity, 8 data bits, 1 stop bit, DB9, PC Interface (2): USB 2.0 Type B
More Information
Attribute Value
Data Sheet Click here to view

Related Products

  1. 5012D
  2. 7020-1-020101
  3. 5017D
  4. 5014
  5. 7022