Attribute | Value |
---|---|
Form Factor |
Explosion proof according to EN 60079-0: 2009
Ex d IIC (explosion proof enclosures) Protection according to EN60529: IP66 Test certificate DEKRA 12 ATEX 0209 Pressure housing type TNCD 191918 Lid: closed / without disc Dimensions: (outside): 190 x 190 x 180 (213) mm (W x H x D) (inside): 170 x 170 x 131 mm (W x H x D) Material: 316L/CF-3M Surface: shot peened |
RoHS | Yes |
Further information |
The Antenna is compliant to the ATEX-Directive 94/9/EC and certificated for Zone 1, an area in which an explosive mixture is likely to occur in normal operation. The ATEX-Directive is an EU directive describing what equipment and work environment is allowed in an area with an explosive atmosphere.
Meinberg's explosion proof antenna consists of a passive antenna and a stainless steel housing including a 40dB amplifier. The stainless steel (AISI-316) housing which is resistant to many environmental impacts, such as sea salt, makes the antenna also suitable for use on offshore platforms. |
Protection | IP66 |
WEEE status of the product | This product is handled as a B2B category product. In order to secure a WEEE compliant waste disposal it has to be returned to the manufacturer. Any transportation expenses for returning this product (at its end of life) have to be incurred by the end user, whereas Meinberg will bear the costs for the waste disposal itself. |
Type of Antenna |
Top centred installed passive antenna, Ex II 2G Ex d IIB T5 (ATEX)
with integrated 40dB amplifier Voltage U = 3 - 16 V DC, Current I typ.= 20mA |
Antenna Connector | type-N connector |
Conformity |
ATEX-Directive 2014/34/EU
EMC-Directive 2004/108/EC RoHS-Directive 2002/95/EC Explosive Atmospheres EN 60079-0:2009 Equipment - General requirements Explosive Atmospheres EN 60079-1:2007 Equipment protection by flameproof enclosures |
Key Features |
Explosion proof according to EN 60079-0: 2012 / EN 60079-1: 2014
Pressure resistant housing with integrated 40dB amplifier |
Operating Temperature | -40°C to +60°C |
Attribute | Value |
---|---|
Data Sheet | Click here to view |