Chroma AC/DC/IR HIPOT TESTER MODEL 19052

Complete Dielctric Testing Solution

The Chroma 19050 Series electrical safety testers are advanced digital hipot testers with load and line regulations that help ensure measurement integrity. The Multi-step capability allows users to perform multiple tests in sequence, such as AC hipot followed by IR.

The Chroma 19052 includes AC/DC hipot testing and IR (Insulation Resistance) measurement.

Key Features

  • ACWV/DCWV/IR 3 in 1 hipot tester
  • Programmable output voltage to 5kV AC and 6kV DC
  • 1kV insulation resistance test
  • Insulation resistance measurement from 1MΩ to 50GΩ
  • Ground continuity check (GC)
  • Standard RS-232 interface
  • Open short check(OSC) function
  • GFI shutdown of the instrument when current imbalance > 0.5mA
  • Flashover (ARC) detection
  • Quick discharge of DUT in IR and DC test
  • Pause mode
  • UL and TUV approved (*see datasheet)
  • CE mark
  • Programmable ramp/fall and test time
  • Programmable high/low limit
  • Save/Recall program test function
  • Remote control and interface support
Contact us for Lead Time

Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.

More Information
Attribute Value
Mode ACWV/DCWV/IR
Insulation Resistance

Test Output Voltage: DC: 0.05~1kV
Voltage Resolution: 2V
Voltage Accuracy: ±(1% of reading + 5 counts) 
IR Range: 1MΩ ~ 10GΩ

Withstanding Voltage Test

Test Output Voltage: AC: 0.05~5kV, DC: 0.05~6kV
Load Regulation: ≦(1% + 5V)
Voltage Resolution: 2V
Voltage Accuracy: ±(1% of reading + 5 counts)
Cutoff Current: AC: 0.1mA ~ 30mA, DC: 0.01mA ~10mA
Cutoff Resolution: AC: 1μA, DC: 0.1μA 
Current Accuracy: ±(1% of reading + 5 counts)
Output Frequency: 50Hz/60Hz
Flashover Detection: AC: 1mA~15mA; DC: 1mA~10mA
Test Time: 0.3 ~ 999.9 sec, continue
Ramp Time: 0.1 ~ 999.9 sec, off
Fall Time: 0.1 ~ 999.9 sec, off
Dwell Time: 0.1 ~ 999.9 sec, off
Waveform: Sine Wave

Memory Storage: Save/Recall 10 tests setups with 60 steps pre setup
Operating Environment Temperature: 0˚C ~ 45˚C; Humidity: 15%~95% RH @ ≦40˚C
Power Consumption 300W
Power Requirements 100V/120V/220V/240V (AC ±10%), 50/60Hz
Dimensions (H x W x D) 270x105x350 mm/10.63x4.13x13.78 inch
Weight 11 kg / 24.23 lbs