Haefely EFT/Burst Immunity Test System | APC Technology Group

2491800

2491800

HAEFELY AG

PEFT 8010 - EFT/Burst Immunity Test System

The Haefely PEFT 8010 is the state-of-the-art EFT/Burst Immunity Test System with a built-in coupling/decoupling network

Designed for single-phase or three-phase mains supply lines and an HV terminal to connect a capacitive coupling clamp IP4B, the spike frequency can be varied from as low as 1Hz to 110kHz.

The PEFT 8010 is capable of generating 999 spikes per millisecond or up to 250 spikes per burst. Its performance fully complies with IEC 61000-4-4:2004, IEC 61000-4-4 Amd.1 Ed.2:01/2010 and IEC 61000-4-4 Ed.3: 03/2012. Pre-programmed standard test routines and several selected user test routines make the PEFT 8010 an optimum standalone solution for both testing during development and final testing of products and sub-assemblies.

Key Features

  • EFT impulse generation according to the newest standards and the latest technology
  • Automatic test operation for the shortest measuring time and minimal setup effort
  • Data exchange to a printer or computer is possible without any additional hardware/software
  • Compact and reliable construction for factory, laboratory or field use
  • A remote control is provided by optional software (WinFEAT&R) designed specially for EMC testing
  • ISO 9001:2000 certified manufactured
  • EFT/Burst Test System according to IEC/EN 61000-4-4 Ed. 1 + 2
  • 7.3kV EFT/Burst voltage
  • Built-in single-phase coupling/decoupling network

For more information on this product, or for expert EMC advice and guidance, start a technical conversation with a member of our team on 0330 313 3220.

Contact us for Lead Time

Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.

More Information
Attribute Value
Included Accessories Cable set, User Manual, Calibration certificate
Dimensions 450 x 570 x 130 mm
Weight 14 kg
Applications
  • Approval Testing
  • Product Development
  • Product Development
  • Industrial
  • Medical
  • Telecommunication
  • Household
Wave Shape: Rise Time

5 ns ± 30% into 50 Ω load
5 ns ± 30% into 1000 Ω load

Wave Shape: Impulse Duration

5 ns ± 30% into 50 Ω load
50 ns – 15 / + 100 ns into 1000 Ω load

Burst Characteristics: Voltage at HV Output 1.0 … 7.3 kV
Burst Characteristics: Voltage at CDN Output 1.0 … 6.6 kV
Burst Characteristics: Spike Frequency 1 Hz … 110 kHz
Burst Characteristics: Burst Duration 0.01 … 999 ms
Burst Characteristics: Burst Period

0.1 Hz … 400 Hz
2.5 ms … 10 s
1 period … 500 periods

Burst Characteristics: Impulses Per Second

max. 250 for Unom > 4 kV
max. 500 for Unom ≤ 4 kV

Burst Characteristics: Impulses Per Burst

max. 75 for Unom > 4 kV
max. 150 for Unom ≤ 4 kV

Burst Characteristics: Spike Distribution Normal, Continuous, Random, Real
Burst Characteristics: Polarity Positive and Negative
Burst Characteristics: Test Time 10 s … 8 h per path
Single Phase: Coupling/Decoupling Network

Maximum AC Voltage: 264 V @ 16 … 440 Hz
Maximum AC Current: 16 A @ 50 … 60 Hz, 10 A @ 400 Hz
Maximum DC Voltage: 125 V
Maximum DC Current: 16 A (dependant on DC voltage)
Coupling Modes: L-GND, N-GND, PE-GND, LN-GND, LPE-GND, NPE-GND, LNPE-GND
Residual Voltage at Test Supply Input: ≤ 10% of applied test voltage

System Configuration

EUT Fail Input: BNC, logic low to trigger
P90 Interface: For a 3-phase CDN extension
PESD Interface: For connecting an ESD generator
Printer Interface: Centronix
Computer Interface: RS-232, IEEE-488 (optional)

Synchronisation

Frequency: 16.6 Hz, 40 Hz, 50 Hz, 60 Hz, 400 Hz, auto
Impulse trigger: Automatic, manual, external

More Information
Attribute Value
Data Sheet Click here to view

Related Products

  1. Haefely EFT/Burst Verification Set According to IEC/EN 61000-4-4
  2. Haefely AXOS 5 EMC Test System According to IEC/EN61000-4-4
  3. Haefely 50 Ω Calibration Attenuator EFT/Burst according to IEC/EN 61000-4-4
  4. Upgrade FP-EFT 100M
  5. Haefely Accessory To Calibrate The Capacitive Coupling Clamp According To IEC/EN 61000-4-4