HI-2602

HI-2602

ETS-Lindgren

Interlock Monitor

The HI-2602 Interlock Monitor continuously monitors microwave fields to protect personnel and equipment, using a patented field-sensing probe with adjustable RF thresholds and integrated alarm functionality for reliable safety assurance.

The HI-2602 Interlock Monitor provides continuous surveillance of microwave fields to safeguard both personnel and equipment, integrating a patented microwave field sensor within a remotely mounted probe.

It is suitable for use in any critical area and can interlock with microwave sources or alarms, with trigger thresholds adjustable up to 10 mW/cm² depending on the model. An LED indicator illuminates while a primary alarm relay activates when the RF field exceeds the preset limit.

The probe’s diode detection array, located at the end of the plastic probe, can sum microwave electric fields of any polarization in a plane perpendicular to the probe axis. Connected via a BNC cable, the probe and main unit are calibrated together as a single, integral instrument, ensuring accurate and dependable operation.

Key Features:

  • Continuous Surveillance of Microwave Fields
  • User Settable RF Level Trigger (10 mW/cm2 Maximum)
Contact us for Lead Time

Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.

More Information
Attribute Value
Configuration
  • HI-2602 Interlock Monitor Probe Assembly with Display
  • 15 m (49.21 ft) Cable
  • Amp Plug, Hood and Pins
  • Calibration Certificate
  • Manual
Input 120 or 240 VAC, 60/50 Hz
Output Form C (SPDT) Relay, 4A (7.5A Peak), 120 VAC
Frequency Response < 1 Sec (0-90% of Pulse Level)
Frequency Range 2450 MHz or 915 MHz (model dependent)
Overload 2.0 W/cm2
Product Category RF Field Monitor