The store will not work correctly in the case when cookies are disabled.
JavaScript seems to be disabled in your browser.
For the best experience on our site, be sure to turn on Javascript in your browser.
DT4222
DT4222
Hioki
Digital Multimeter DT4222 - Premier Pocket DMM with CAT IV 300 V, CAT III 600 V Safety
The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The DT4222 is a pocket-sized digital multimeter designed specifically for general purpose testing, with ±0.5% DC V accuracy and wide 40 Hz to 1 kHz AC V bandwidth.
CAT IV 300 V, CAT III 600 V
More Information
Attribute
Value
Key Features
Achieving a high level of safety in a compact body and lightweight design Resistance, Capacitance measurement and diode testing (DT4222) Robust design capable of withstanding a drop from a height of 1 m Test leads conveniently wrap around the back ±0.5% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms) Broad -10 to 50°C (14°F to 122°F) operating temperature range
Basic Specifications
DC Voltage range
600.0 mV to 600.0 V, 4 ranges, Basic accuracy: ±0.5 % rdg. ±5 dgt.
AC Voltage range
6.000 V to 600.0 V, 3 ranges, Frequency characteristics: 40 Hz - 1 kHz
Basic accuracy 40 - 500 Hz : ±1.0 % rdg. ±3 dgt. (True RMS, crest factor 3)
Resistance range
600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.9 % rdg. ±5 dgt.
Capacitance range
1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt.
Frequency range
AC V measurement: 99.99 Hz (5 Hz or more) to 9.999 kHz, 3 ranges
Basic accuracy: ±0.1 % rdg. ±2 dgt.
Continuity Check
Continuity threshold [ON]: 25 Ω or less (buzzer sound), [OFF]: 245 Ω or more
Response time: 0.5 ms or more
Diode test
Open terminal voltage: 2.5 V or less, Testing current 0.5 mA or less,
Threshold of forward voltage: 0.15 V to 1.5 V
Voltage Detection
N/A
Other functions
Filter function, display value hold, relative value display, auto-power save
Display
Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
Display refresh rates
5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s )
Power supply
LR03 alkaline batteries ×1, Continuous use: 40 hours (back light OFF)
Dimensions and mass
72 mm (2.83 in) W × 149 mm (5.87 in) H× 38 mm (1.50 in) D,190 g (6.7 oz) (with batteries and holster)
Accessories
Test Lead DT4911 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×1