CT6701
CT6701
Hioki
Current Probe
High S/N characteristic ideal for ultra low 1 mA order current waveforms
Clearly Observe Even 1 mA Waveforms
Hioki flat bandwidth current probes are best-in-class current sensors for use with Memory HiCorders and high performance oscilloscopes. The CT6701 is a high-sensitivity current probe that offers a wide DC to 120 MHz bandwidth and 5A of continuous input, and applications include capturing transient current signals from switching power supplies, inverters, and motor controllers.
The probe is designed with a high permeability magnetic shield with low insertion loss to reduce derating that may result from increased sensor head heating caused by eddy currents, making it ideal for measuring current of low impedance circuits and waveforms that include high frequency components.
Use with an instrument with a high input impedance of 1 MΩ or higher.
Key Features
- Wide band: DC to 120 MHz (-3 dB)
- High S/N characteristic ideal for ultra low 1 mA order current waveforms
- Connect directly to an oscilloscope’s BNC input terminal *1
Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.
Attribute | Value |
---|---|
Power Supply | ±12 V ±0.5 V, 3.2 VA |
Included Accessories | Instruction manual ×1, Carrying case ×1 |
Max Allowable Input | 5 A rms (DC, and sine wave, requires derating at frequency) |
Dimensions and Weight | Sensor: 155 mm (6.10 in)W × 18 mm (0.71 in)H × 26 mm (1.02 in)D, Terminator: 29 mm (1.14 in)W × 83 mm (3.27 in)H × 40 mm (1.57 in)D mm, Mass: 250 g (8.8 oz), Sensor cable BNC terminal: 1.5 m (4.92 ft), Power cable: 1 m (3.28 ft), Power plug: FFA.0S.304.CLAC37Y / LEMO inc. |
Basic Accuracy | Typ.: ±1% rdg. ±1 mV (DC, 45 to 66 Hz sine wave, 0 to 5 A rms) Guaranteed: ±3% rdg. ±1 mV (DC, 45 to 66 Hz sine wave, 0 to 5 A rms) |
Frequency Bandwidth | DC to 120 MHz (-3 dB) |
Output Voltage Rate | 1 V/A (The output of this probe is internally terminated) |
Core Diameter | φ 5 mm (0.20 in) |
Rise Time | 2.9 ns or shorter |
Noise Level | 60 μA rms typical, 75 μA rms max (for 30 MHz band measuring instrument) |