ST5520

ST5520

ST5520

Hioki

Insulation Tester ST5520 - Industry's Fastest Insulation Tester Assesses in as Fast as 50 ms

The Hioki electrical safety testers are designed for insulation resistance and voltage withstand testing of electrical devices and components according to various safety standards. The ST5520 is the fastest insulation tester in the industry, delivering pass/fail assessment in as fast as 50 ms. 25 V to 1000 V test voltage with 1 V resolution.
Contact us for lead time

Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.

More Information
Attribute Value
Key Features
  • Rapidly assess in as fast as 50 ms
  • Quick discharge of residual voltage
  • Freely configurable test voltage (set from 25 V to 1000 V, 1 V resolution)
  • Contact check function (prevents errors due to poor contact)
  • Short-circuit check function (stops potential defects from reaching the market)
  • Ideal for battery production lines
Basic Specifications
Measurement items Insulation resistance (Applied DC voltage method)
Testing voltage (Measurement range: AUTO/MANUAL setting is possible)
25 V ≤ V < 100 V (2.000/20.00/200.0 MΩ),
100 V ≤ V < 500 V (2.000/20.00/200.0/2000 MΩ),
500 V ≤ V ≤ 1000 V (2.000/20.00/200.0/4000 MΩ)
Basic accuracy ±2 % rdg. ±5 dgt.
25 V ≤ V < 100 V [0 to 20 MΩ]
100 V ≤ V < 500 V [0 to 20 MΩ]
500 V ≤ V ≤ 1000 V [0 to 20 MΩ]
Measurement speed Fast: 30 ms/time, Slow: 500 ms/time (selectable)
Display LCD (service life: 100,000 hours), 4-level backlight
Internal memory Saved items: rated measurement voltage, comparator upper limit /lower limit values, test mode, beep sound to distinguish the result, test time, response time, resistance range, measurement speed
Memory capacity: up to 10 items (can be saved/loaded)
Comparator setting UPPER_FAIL: Measured value ≥ upper limit value
PASS: Upper limit value > measured value > lower limit value
LOWER_FAIL: Measured value ≤ lower limit value
Judgement process Beep sound, PASS / U.FAIL/L. FAIL: light up on LED display, When UL_FAIL, U.FAIL / L.FAIL light up simultaneously, EXT.I/O output, judgement result can be obtained via RS-232C
Test duration Definition of test duration: Test duration = Response time + Measurement time
Function: Set the time from voltage application until pass/fail assessment
Configuration range: 0.045 s to 999.999 s (0.001 s resolution)
Response time timer After the start of the test, comparator judgment operation can be prohibited until a set interval from 0.005 sec. to 999.999 sec. (at 0.001 sec. resolution) has passed.
Analog output DC +4 V f.s.
Interface RS-232C (standard), External I/O (External control input, Judgment result)
BCD output (ST5520-01 only)
Power supply 100 to 240 V AC, 50/60 Hz, 25 VA max.
Dimensions and mass 215 mm (8.46 in)W × 80 mm (3.15 in)H × 166 mm (6.54 in)D, 1.1 kg (38.8 oz)
Accessories Instruction Manual ×1, Power cord ×1, EXT. I/O Connector ×1, Connector Cover ×1
Instrument Type Insulation Resistance Tester
Notes The ST5520 and ST5520-01 cannot be operated alone. Please select and purchase the optional test leads to accommodate your application.
More Information