Meinberg LANTIME M450 | APC Technology Group

LANTIME M450

LANTIME M450

Meinberg

Robust Rail Mount NTP Time Server with internal Meinberg reference clock

The LANTIME M450 Time Server offers unparalleled flexibility and versatility and provides accurate time to your network in a compact and full-featured DIN railmount package for industrial applications such as power generation, transmission and distribution (substation automation), process control and industrial automation systems. The M450 includes an LC-Display and keypad and an extremely broad range of available options.

The LANTIME M450 time server is available with an integral receiver as well as an IRIG timecode reader and can be customised with a lot of different options to deliver exactly the feature set that is required for a certain application/environment.

Ultra-compact Form Factor

The ultra-compact form factor enables this NTP system to become the ideal time and frequency source in installations where every millimetre counts. With up to 6 network ports, this NTP appliance offers the highest port density.

Simple System Configuration

As with most LANTIME M-Series models, a large LCD panel showing the state of the internal time signal receiver and the NTP subsystem is combined with three bicolor LEDs (green/red) that indicate the status of the three main components: Reference Time (e.g. GPS or GLONASS), Time Synchronization Service (NTP) and Network (Link status). A fourth red LED is labelled ALARM and can be configured to signal any event that is covered by the notification handling routines.

Oscillator Options

The LANTIME M450 GPS is equipped with a high precision oscillator "TCXO" (look at oscillator options for details). The oscillator determines the holdover characteristics (e.g. when a reference source signal like GPS is disturbed or jammed). For applications with higher stability/holdover requirements, there are several oscillator options available (up to "OCXO HQ").

Modular System Architecture

Because of its modular system architecture, it is possible to equip a LANTIME M450 time server with a number of different reference time sources. Optionally several additional frequency, serial string and pulse outputs are available as well as power supplies for additional input voltage ranges.

In addition to the standard electrical interfaces, a lot of output signals can be delivered on optical ports, too.

Contact us for lead time

Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.

More Information
Attribute Value
Manual URL https://www.meinbergglobal.com/download/docs/manuals/english/setup-guide_d.pdf
Technical Support Meinberg offers free lifetime technical support via telephone or e-mail. Additonaly, APC's own team of time synchronisation specialists are available for first line technical support.
Power Consumption 30W
Form Factor Fischer aluminium housing for DIN mounting rail
Relative Humidity Max. 85%
RoHS Yes
Control elements Eight push buttons to set up basic network parameters and to change receiver settings
Status info

Four Bicolor LEDs showing the status of:

  • Reference time
  • Time service
  • Network
  • Alarm
Frequency Outputs

10 MHz via female BNC connector, TTL into 50 Ohm
Accuracy depends on the oscillator (standard: TCXO)

Pulse outputs Pulse Per Second (PPS), TTL level, pulse width: 200 ms
Accuracy of Pulse Outputs

Depends on oscillator option:

  • < ±100ns (TCXO, OCXO LQ)
  • < ±50ns (OCXO SQ, OCXO MQ, OCXO HQ, OCXO DHQ)
Network Interface

2 network ports

  • 1 x 10/100/1000Base-T RJ45
  • 1 x 1000Base-T SFP Slot

    Up to 25,000 NTP requests/second

Universal Serial Bus (USB) Ports

1 x USB port on the front panel for:

  • Installing firmware upgrades
  • Performing backups and restoration of configuration files
  • Copying security keys
  • Locking & unlocking front buttons
Data format of interfaces

COM 0:

  • Baudrate: 300, 600, 1200, 2400, 4800, 9600, 19200 Baud
  • Data Format: 8E1, 8E2, 8N1, 8N2, 8O1, 7E1, 7E2, 7N2, 7O1, 7O2
  • Time Telegram: Meinberg Standard-Telegram , SAT, NMEA RMC, Uni Erlangen (NTP), COMPUTIME, Sysplex, Capture-Telegramm, SPA, RACAL, Meinberg GPS, NMEA GGA, NMEA RMC GGA, NMEA ZDA, ION, 6021 or IRIG-J
CPU
  • Intel® Atom™ Processor E Series (2 Cores, 1.33GHz, TDP 3W)
  • Main memory: onboard 2 GB
  • Cache memory: 1MB 2nd Level Cache
  • Flash disk: 4 GB
Operating System of the SBC Custom LANTIME OS based on Linux 4.x LTS Kernel
Network protocols OSI Layer 4 (transport layer)
  • TCP
  • UDP
Network protocols OSI Layer 7 (application layer)
  • Telnet
  • FTP
  • SSH (including SFTP, SCP)
  • HTTP
  • HTTPS
  • syslog
  • SNMP
Internet Protocol (IP)
  • IPv4
  • IPv6
Network Autoconfiguration Support
  • IPv4: Dynamic Host Configuration Protocol - DHCP (RFC 2131)
  • IPv6: Dynamic Host Configuration Protocol - DHCPv6 (RFC 3315) and Autoconfiguration
  • Networking - AUTOCONF (RFC 2462)
Network Time Protocol (NTP)
  • NTP v2 (RFC 1119), NTP v3 (RFC 1305), NTP v4 (RFC 5905)
  • SNTP v3 (RFC 1769), SNTP v4 (RFC 4330)
  • MD5 / SHA-1 authentication and autokey key management
Parallel Redundancy Protocol (PRP) PRP (IEC 62439-3)
Time Protocol (TIME) Time Protocol (RFC 868)
IEC 61850 Synchronisation of IEC 61850-compliant devices using SNTP
Hypertext Transfer Protocol (HTTP) HTTP(S) for web interface and REST API access
Secure Shell (SSH)
  • SSH v1.3
  • SSH v1.5
  • SSH v2 (OpenSSH)
Telnet Telnet (RFC 854-RFC 861)
Scope of supply Included in delivery is a Meinberg outdoor antenna incl. mounting kit, pre-assembled antenna cable, CAB-CONSOLE-RJ45 cable for initial setup and documentation on USB storage.
Firmware Updates Firmware is field-upgradeable, updates can be installed directly from the unit or via a remote network connection. Software updates are provided free of charge for the lifetime of your Meinberg product.
WEEE status of the product This product is handled as a B2B category product. For disposal, it must be returned to the manufacturer to ensure WEEE compliance. Any transportation expenses for returning this product (at end-of-life) must be covered by the end user, while Meinberg will cover the costs for the waste disposal itself
Supported PTP Profiles
  • SNMPv1 (RFC 1157)
  • SNMPv2c (RFC 1901-1908)
  • SNMP v3 (RFC 3411-3418)
Supported Time String Formats
  • Meinberg Standard Timestring
  • Uni Erlangen Timestring
  • SYSPLEX Timer
  • NMEA
  • Computime
  • ABB-SPA
  • SAT
  • Arbiter
Key Features
  • Selectable Reference Sources:
    • GPS: Satellite receiver for the Global Positioning System
    • GNS: Combined GPS/GLONASS/Galileo/BeiDou satellite receiver (L1 frequency band), can also be used for mobile applications
    • GNS-UC: GPS and Galileo satellite receiver with up-converter for Meinberg GPS antenna/converter
    • PZF: DCF77 correlation receiver for middle Europe
    • MSF: Long wave receiver for Great Britain
    • TCR: Time code receiver for IRIG A/B, AFNOR or IEEE1344 codes
    • MRS: (GPS, PPS, 10MHz, NTP): Multi Reference Source - several reference sources, adjustable following priority of signal

  • Synchronises NTP-compatible clients with support for NTP, SNTP, and NTS
  • Web interface that is both powerful and easy to use
  • Backlit LCD panel and function keys for local configuration
  • Comprehensive networking support, including full HTTPS encryption for Web Interface and REST API with TLS certificate management
  • Frequency signals and industry-specific sync signals via additional optional outputs
  • USB port for installation of firmware updates, backup/restore of configuration and log files, and disabling/enabling access to front panel controls
  • Command line interface for advanced power users with absolute control over every facet of the server's functionality
  • Support for syslog, SNMP, and SMTP for comprehensive event logging, network integration, and notification functionality
  • GNS models include Multi-GNSS antenna for reception of GPS, Galileo, BeiDou, and GLONASS signals
  • GPS and GNS-UC models include Meinberg IF antenna of reception of GPS signals and, with GNS-UC models, also Galileo signals
Operating Temperature 0 - 50°C
Interface Single serial RS-232 interface (no serial interface in case of an internal time code receiver).
Power Supply

Standard:

100-240 V AC (50-60 Hz) / 100-240 V DC

Low DC option:

48 V DC

Dimensions 105 x 189 x 146mm
Display LC-Display, 4 x 16 Characters
More Information
Attribute Value
Data Sheet Click here to view

Related Products

  1. microSync Broadcast
  2. SyncFire
  3. LANTIME M100
  4. LANTIME M150
  5. LANTIME M900