WP400-3
WP400-3
Wavecontrol
WP400-3 field probe 1 Hz to 400 kHz
Capable of measuring E and H fields from 1 Hz to 400 kHz selective and broadband the WP400-3 field probe is compatible with Wavecontrol’s SMP2 equipment.
Uses include:
IEC/EN 62233
Household appliances and similar apparatus: Measurement methods for electromagnetic fields with regard to human exposure.
IEC/EN 62822
Electric welding equipment: Assessment of restrictions related to human exposure to electromagnetic fields.
IEC/EN 62311
Assessment of electronic and electrical equipment for which no dedicated product- or product family standard regarding human exposure to electromagnetic fields applies.
Uses include:
IEC/EN 62233
Household appliances and similar apparatus: Measurement methods for electromagnetic fields with regard to human exposure.
IEC/EN 62822
Electric welding equipment: Assessment of restrictions related to human exposure to electromagnetic fields.
IEC/EN 62311
Assessment of electronic and electrical equipment for which no dedicated product- or product family standard regarding human exposure to electromagnetic fields applies.
Contact us for lead time
Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.
Attribute | Value |
---|---|
Key Features |
|
Frequency Range | 1 Hz – 400 kHz |
Linearity |
± 1 % (typ.) ± 2 % (max.) |
Resolution |
Electric Field: < 0.4 mV/m above 8 Hz Magnetic Field: < 0.3 nT (at 50 Hz) and < 0.15 nT above 100 Hz |
Display | RMS, Axis Values, AVG, MAX, MIN, PEAK, RMS time graph |
Accessory Type | Probe |
Probe Measurement Range |
Electric Field: 10 V/m to 400 kV/m Magnetic Field: 200 nT - 50 mT (100 Hz - 10 kHz) · Upper range increases linearly with decreasing frequency below 100 Hz. · Upper range decreases linearly with increasing frequency above 10 kHz. |
Peak Value | digital realtime |
Noise Level |
Electric Field: < 10 V/m (10 Hz - 400 kHz) Magnetic Field: < 200 nT (10 Hz - 400 kHz) |
Damage Level |
Electric Field: > > 600 kV/m Magnetic Field: > 5000 mT up to 60 Hz Damage level decreases linearly with increasing frequency above 60 Hz |
Temperature Deviation |
Electric Field: - 0.005 dB/°C (- 15 °C to 40 °C) Magnetic Field: - 0.003 dB/°C (- 15 °C to 25 °C), + 0.003 dB/°C (25 °C to 40 °C) |
Typical Uncertainty |
Electric Field: 0.67 dB Magnetic Field: 0.60 dB |
Isotropy |
Electric Field: ± 5% Magnetic Field: ±4 % |
Applications |
|
Sensor Type |
Electric Field: Isotropic electrode Magnetic Field: Isotropic 3 cm2 coils |
Dimensions | 275 x 33 mm Ø |
Attribute | Value |
---|---|
Data Sheet | Click here to view |