CM4002
CM4002
Hioki
AC Leakage Clamp Meter
Prevent unexpected downtime!
Identify potential problems and avoid large problems
Key Features
- Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
- Detect minuscule leakage currents with a newly designed sensor. (Core jaw diameter up to φ 40 mm)
- Broad measurement range extending from leakage currents to load currents
- Complies with the performance standard set forth in IEC/EN 61557-13, an international standard on leak clamp meters
- Solve GFCI and RCD problems quickly
- Speed up pass/fail judgments with the built-in comparator function
- CAT IV 300 V
- CAT III 600 V
Contact us for lead time
Click below to request a quote for this item. Or for product advice, stock and lead time enquiries call our team on 0330 313 3220.
Attribute | Value |
---|---|
Power Supply | AA-size alkaline battery (LR6) × 2; Continuous operating time: 48 hr. (without Z3210 installed), 30 hr. (with Z3210 installed and using wireless communications) |
Included Accessories | Carrying case C0203 × 1, Instruction manual × 1, Operating Precautions × 1, AA-size alkaline battery (LR6) × 2 |
Display | Display refresh rate: 5 times/s |
Dimensions and Weight | 64 mm (2.52 in) W × 233 mm (9.17 in) H × 37 mm (1.46 in) D, 400 g (14.1 oz.) |
Other Functions |
Filter Function: Cut off frequency: 180 Hz ±30 Hz at filter ON (-3 dB) Max/ Min/ AVG/ PEAK MAX/ PEAK MIN value display, Display value hold and auto hold; Backlight, Auto power save, Buzzer sound, Event count display, Comparator, Simple event recording, Rush current measurement |
Core Jaw Diameter | φ 40 mm (1.57 in.) |
AC Current Range |
6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS |
Frequency Range | 15.0 Hz to 2000 Hz |
Attribute | Value |
---|---|
Data Sheet | Click here to view |